Guyed masts

Participants
Owner : TERNA ENERGY SA

Location
Wind farms in Greece

General Information
Structural Type : Truss masts with three groups of guys
Function / usage : Wind measurements
Date of study : 2003

Geometry

Mast : Steel truss with triangular plan view
Guys : Three groups anchored at four different levels
Max height : 65,00m

Loads

Self weight
Live load
Wind
Snow
Temperature difference
Seismic load (0,36g)
Rupture of one guy

Materials

Masts : structural steel S235
Bolts : 10.9
Guys : Stainless steel AISI 316
Foundation : Reinforced concrete C16/20